Roofing calculator

Ice and water shield calculator

60 ft of eave with 3 ft of coverage plus 24 ft of valley is 252 ft². A 200 ft² roll with 10% waste rounds to 2 rolls. In metric, membrane area is 23.41 m².

Formula. (eave + valley) × coverage up the roof × (1 + waste) ÷ roll coverage

Self-adhered ice-and-water roll count from eave length, coverage up the roof and valley length.

By Feroz Sheikh · Our math isn't hidden: see the formula, waste allowance and rounding rule. Formula ROOF-IWS-001 v1.0.0

Math shown

See the formula, waste and rounding.

Formula IDROOF-IWS-001v1.0.0

Project inputs

Enter your measurements. Switching units converts the same project, including coverage and unit rates. Package yields keep the unit printed beside each field.

Refine measurements and rates at any time. Your current values are included in the material-list PDF.

Calculated result

2rolls

Rolls to order

Formula, waste and rounding are shownROOF-IWS-001

(eave + valley) × coverage up the roof × (1 + waste) ÷ roll coverage

252 ft²

Membrane area

277.2 ft²

Area including waste

Planning estimate, not engineering advice. Confirm site measurements and product specifications. Calculation limits.

Ice and water shield: measurement diagram. Measure only the edge, ridge, hip or valley runs requested in the fields; these are not interchangeable.
Measure only the edge, ridge, hip or valley runs requested in the fields; these are not interchangeable. View image

Multiply eave length by how far the membrane runs up the roof, add valley length at the same width, then divide by net roll coverage after a visible lap allowance.

  1. Measure every eave that needs the membrane, including porches if they are in the spec.
  2. Enter how far up the roof the product must run. That is a code and climate input, not a default you should leave blind.
  3. Add valleys, around skylights and at wall intersections as extra length.

Add your project costs

Enter supplier prices and any labour, equipment or delivery costs. Pick a currency — badges, inputs, and totals follow.

Costs use the square, bundle or panel rate you type. Construclytic does not fetch shingle or metal prices. Tear-off, dumpsters, starter and flashing stay separate estimate lines. For GCC projects, select QAR, AED, SAR, KWD, OMR or BHD and enter local supplier rates.

View estimate Quote / invoice Add another item

How this calculator works

A transparent ice and water shield takeoff.

Multiply eave length by how far the membrane runs up the roof, add valley length at the same width, then divide by net roll coverage after a visible lap allowance.

ROOF-IWS-001 counts self-adhered rolls from eave length, coverage up the roof and valley length. Felt underlayment is a different calculator. This is a coverage count, not an ice-dam design.

Worked example. Example: 60 ft of eave with 3 ft of coverage plus 24 ft of valley is 252 ft². A 200 ft² roll with 10% waste rounds to 2 rolls.
See the example inputs and calculated result

This separate example uses the calculator's starting values in imperial units. It stays unchanged when you edit the tool above. Example rates, yields and dimensions are assumptions, not recommendations for your project.

Ice and water shield: example inputs
InputExample value
Eave length60 ft
Coverage up the roof3 ft
Valley length24 ft
Roll coverage200 ft²
Waste factor10 %

Example result: Rolls to order — 2 rolls.

(eave + valley) × coverage up the roof × (1 + waste) ÷ roll coverage

Use the labelled units above when reproducing this example. To work in metric, switch the calculator to Metric; applicable measurements are converted, while product-specific units remain labelled.

  1. 1. Measure every eave that needs the membrane, including porches if they are in the spec.
  2. 2. Enter how far up the roof the product must run. That is a code and climate input, not a default you should leave blind.
  3. 3. Add valleys, around skylights and at wall intersections as extra length.

Field notes that change the number

  • Eaves usually run from the drip to a stated distance inside the warm wall — enter that coverage width.
  • Valleys are extra linear coverage.
  • Enter the labelled roll coverage after laps.

Common mistakes

  • Using felt rolls as ice-and-water.
  • Ignoring valleys.
  • Calling this a code-minimum check without the local rule.

Need the broader workflow? Read the roofing planning guide.

Questions

Questions about ice and water shield

Is 3 ft the code width?

No. It is a common cold-climate planning figure. Local code may want 24 in inside the wall line, or from eave to a stated distance. Confirm before you order.

Is this underlayment?

Ice-and-water is a self-adhered membrane at eaves and valleys. Field underlayment is a different roll — use the underlayment calculator for the rest of the roof.

What is the formula ID?

This ice and water shield calculator publishes formula ROOF-IWS-001, version 1.0.0. The ID stays on the result and on the estimate line.